Nuclear (gamma) level transmitter
ISA 5.1-2009/2022 (primary element symbols) / PIP PIC001
Drawn as
A source holder (small box) on one side of the vessel and a detector rod on the other, joined by a wavy (radiation) line across the vessel, with an LT bubble on the detector.
Meaning
Gamma level or density measurement through the vessel wall: slug catchers, desanders, profilers in separators. Needs radiation controls. No dedicated component.
Variants
- The source holder may be marked with the radiation trefoil or "RS"
- Density profilers have many detectors in a vertical row
Tags
LT · RE · LT · RE
No 3D component yet.