Orifice flowmeter

Orifice meter run: ASME B16.36 weld-neck orifice flange pair (class 300 minimum, 1.5 in minimum thickness) with paddle plate with a bored orifice (beta prop) and a stamped tab, spiral-wound gaskets, studs and jack screws. Flange taps 1 in from each face (the opposite pair plugged) feed root valves and close-coupled tubing to a 5-valve manifold and DP transmitter. Upstream and downstream straight lengths are set in pipe diameters.

ISO 5167-2ASME B16.36ASME B16.5AGA 3 / API MPMS 14.3
Drag to orbit, scroll to zoom
Parameters
–
– D
– D

Installation

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add orifice-flowmeter

Copies instruments/orifice-flowmeter.tsx and the shared lib/ into src/components/deck-twin/. Needs three, @react-three/fiber and @react-three/drei. See installation for the manual route.

Usage

import { Canvas } from '@react-three/fiber'
import { OrbitControls } from '@react-three/drei'
import { Stage } from './components/deck-twin/lib/stage'
import { OrificeFlowmeter } from './components/deck-twin/instruments/orifice-flowmeter'

export default function Scene() {
  return (
    <Canvas shadows camera={{ position: [8, 5, 9], fov: 35 }}>
      <Stage>
        <OrificeFlowmeter />
      </Stage>
      <OrbitControls makeDefault />
    </Canvas>
  )
}

Props

PropTypeDefaultRange
npsnumber (NPS, in)null
rating150 | 300 | 600 | 900 | 1500 | 2500null
betanumbernull0.2 – 0.75
upstreamnumber (D)null2 – 20
downstreamnumber (D)null2 – 10
housing"actuatorBlue" | "stainless" | "aluminium" | "equipmentPaintDark"null
tagstringnull
...groupposition, rotation, scale…

P&ID

P&ID symbol for orifice-flowmeter

Two short parallel bars across the line (the orifice flanges with the plate between them), tagged FE, with two taps to an FT or FIT bubble. Some legends draw a single bar, or a box around the line with a diagonal.

tag FEISA FEISA FTISA FITISA FOISA 5.1 (orifice plate in flanges, FE + FT)

With no transmitter and tag RO or FO it is a restriction orifice, not a meter. Venturi and flow nozzle are drawn as a converging / diverging outline instead. A flanged meter run with 10D / 5D straight lengths and a flow conditioner is still this element. ISA codes here: FO = restriction orifice.

Orifice plate / flow element specification form (ISA-TR20.00.01; ISO 5167-2 calculation) fields and the props they set
Line sizenps
Flange ratingrating
Beta ratio (d/D)beta
Upstream straight lengthupstream
Downstream straight lengthdownstream
Tag numbertag

For agents

Machine-readable entry with props, ranges, defaults and ports:

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info orifice-flowmeter

Or fetch /r/orifice-flowmeter.json, or copy a ready-made instruction:

Add the Deck Twin "Orifice flowmeter" component to this project. Run `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add orifice-flowmeter` (it copies the file and the shared lib into src/components/deck-twin/), then `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info orifice-flowmeter` for its props, ranges and ports. Render <OrificeFlowmeter /> inside a React Three Fiber <Canvas shadows>, wrapped in <Stage> from src/components/deck-twin/lib/stage. Set props from my data (metres, NPS in inches, ASME class) and leave the rest at defaults. Install three, @react-three/fiber, @react-three/drei and @types/three if they're missing. Full guide: https://decktwin.com/skill/SKILL.md