Dual plate check valve dimensions: API 594

A dual-plate check valve has two spring-loaded half discs on a central hinge pin. The Type A wafer body is clamped between two pipe flanges, and API 594 sets its face-to-face length.

face to facepipe flange
The body length is the face-to-face between the two pipe flanges it is clamped between.

Reference values transcribed for visualisation. This is not a copy of API 594 and does not replace it. Check every value against the current edition before design, procurement or fabrication.

Values were transcribed from API 594 in millimetres. Inches are converted from the millimetres and rounded to 0.01 in.

Standard: API 594

Values switch where the heading or table title shows mm or in. NPS, DN, bolt counts and bolt sizes stay as they are.

API 594 Type A wafer face-to-face

NPSDNClass 150 (mm)Class 300 (mm)Class 600 (mm)
250606060
2-1/265676767
380737373
4100737379
61509898136
8200127127165
10250146146213
12300181181229
14350184222273
16400191232305
18450203264362
20500219292368
24600222318438

Class 900 and above are left out: the library holds them only as approximate values.

How to read the table

Find the NPS and read the length for the class. Some neighbouring sizes share a length, for example NPS 3 and 4 at Class 150.

Worked example

An NPS 6 Class 300 dual-plate check is 98 mm (3.86 in) long, against 17.50 in (445 mm) for a flanged swing check.

Questions

What is the face to face of a 4 inch Class 150 dual plate check valve?

73 mm (2.87 in) for an API 594 Type A wafer valve.

Can a dual-plate check be installed in a vertical line?

Usually in vertical lines with upward flow, as long as the valve maker allows it. The spring closes the plates without relying on gravity.

3D components sized from these values 2