Surge arrester (station class)

Station-class metal-oxide surge arrester on a tubular support: one to four stacked housed units (by system voltage) with pressure-relief vents, top terminal and a hanging grading ring from 145 kV. It stands on an insulating base of four small post insulators, with an insulated lead to a surge counter / leakage monitor on the column and an earth lead to an inspection pit.

IEC 60099-4IEC 60099-5IEC 61936-1
Drag to orbit, scroll to zoom
Parameters

Installation

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add surge-arrester

Copies onshore/surge-arrester.tsx and the shared lib/ into src/components/deck-twin/. Needs three, @react-three/fiber and @react-three/drei. See installation for the manual route.

Usage

import { Canvas } from '@react-three/fiber'
import { OrbitControls } from '@react-three/drei'
import { Stage } from './components/deck-twin/lib/stage'
import { SurgeArrester } from './components/deck-twin/onshore/surge-arrester'

export default function Scene() {
  return (
    <Canvas shadows camera={{ position: [8, 5, 9], fov: 35 }}>
      <Stage>
        <SurgeArrester />
      </Stage>
      <OrbitControls makeDefault />
    </Canvas>
  )
}

Props

PropTypeDefaultRange
kv72.5 | 145 | 245 | 420null
insulation"porcelain" | "composite"null
tagstringnull
...groupposition, rotation, scale…

P&ID

P&ID symbol for surge-arrester

Single-line: a rectangle (non-linear resistor) with an arrow inside pointing to earth, connected from the line to the earth symbol, usually at transformer terminals and line entries.

tag SAtag LAIEC 60617 (single-line diagram); IEC 60099-4

Rectangle with an internal arrow to earth = surge arrester; a plain rectangle to earth on a neutral is a neutral earthing resistor. LA (lightning arrester) is an older name.

Surge arrester datasheet (IEC 60099-4) fields and the props they set
System voltagekv
Housing insulationinsulation
Tag numbertag

For agents

Machine-readable entry with props, ranges, defaults and ports:

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info surge-arrester

Or fetch /r/surge-arrester.json, or copy a ready-made instruction:

Add the Deck Twin "Surge arrester (station class)" component to this project. Run `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add surge-arrester` (it copies the file and the shared lib into src/components/deck-twin/), then `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info surge-arrester` for its props, ranges and ports. Render <SurgeArrester /> inside a React Three Fiber <Canvas shadows>, wrapped in <Stage> from src/components/deck-twin/lib/stage. Set props from my data (metres, NPS in inches, ASME class) and leave the rest at defaults. Install three, @react-three/fiber, @react-three/drei and @types/three if they're missing. Full guide: https://decktwin.com/skill/SKILL.md