System cabinet row (DCS / SIS / F&G / server)

Row of count baying cabinets (800 × 800 × 2000 mm on a 100 mm plinth by default, RAL 7035) for DCS, SIS or F&G controllers, field marshalling or servers. Glazed, perforated or solid front doors hinged on the right with swing-handle locks and label strips, SIS / F&G status lamps, rear doors with vents, side panels and roof cable-entry brushes, cabinet lights. Behind the door: zinc mounting plate with trunking, I/O carriers with status LEDs, terminal rows and power supplies, or 19" rails full of servers and switches. Cables rise through bottom gland plates from a raised floor. open swings the front doors.

IEC 61439IEC 60297 (19" racks)IEC 60529 (IP54)
Drag to orbit, scroll to zoom
Parameters
–
–

Installation

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add system-cabinet

Copies interiors/system-cabinet.tsx and the shared lib/ into src/components/deck-twin/. Needs three, @react-three/fiber and @react-three/drei. See installation for the manual route.

Usage

import { Canvas } from '@react-three/fiber'
import { OrbitControls } from '@react-three/drei'
import { Stage } from './components/deck-twin/lib/stage'
import { SystemCabinet } from './components/deck-twin/interiors/system-cabinet'

export default function Scene() {
  return (
    <Canvas shadows camera={{ position: [8, 5, 9], fov: 35 }}>
      <Stage>
        <SystemCabinet />
      </Stage>
      <OrbitControls makeDefault />
    </Canvas>
  )
}

Props

PropTypeDefaultRange
countnumbernull1 – 12
system"dcs" | "sis" | "fg" | "marshalling" | "server"null
width0.6 | 0.8 | 1.2null
depth0.6 | 0.8 | 1null
height1.8 | 2 | 2.2null
door"glazed" | "perforated" | "solid"null
opennumbernull0 – 1
rearDoorsbooleannull
cableEntrybooleannull
tagstringnull
...groupposition, rotation, scale…

P&ID

P&ID symbol for system-cabinet

Plan view: a row of squares (cabinets) against a wall or back to back, with door swing arcs on the front and the system (DCS, SIS, F&G, marshalling) written on each; front and rear access clearances dashed.

Layout plan convention (architectural / control room layout, ISO 11064) / equipment room layout

Only on equipment-room layouts. Switchgear line-ups look similar but are deeper and labelled with feeders.

Cabinet layout / system cabinet specification (IEC 61439, IEC 60297) fields and the props they set
Number of cabinetscount
Systemsystem
Widthwidth
Depthdepth
Heightheight
Front doordoor
Rear doorsrearDoors
Cable entrycableEntry
Tag numbertag

Typical suppliers

Rittal · Emerson. The geometry is generic and sized from public standards. It is not vendor CAD.

For agents

Machine-readable entry with props, ranges, defaults and ports:

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info system-cabinet

Or fetch /r/system-cabinet.json, or copy a ready-made instruction:

Add the Deck Twin "System cabinet row (DCS / SIS / F&G / server)" component to this project. Run `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add system-cabinet` (it copies the file and the shared lib into src/components/deck-twin/), then `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info system-cabinet` for its props, ranges and ports. Render <SystemCabinet /> inside a React Three Fiber <Canvas shadows>, wrapped in <Stage> from src/components/deck-twin/lib/stage. Set props from my data (metres, NPS in inches, ASME class) and leave the rest at defaults. Install three, @react-three/fiber, @react-three/drei and @types/three if they're missing. Full guide: https://decktwin.com/skill/SKILL.md