Control valve face to face dimensions: ISA 75.08.01

ISA 75.08.01 sets the face-to-face of flanged globe-style control valves, so that a control valve from one maker can replace another in the same pipe gap. IEC 60534-3-1 covers the same subject.

The lengths here are for raised-face flanged bodies. Ring-joint bodies are longer. None of these lengths match ASME B16.10 manual globe valves.

face to face
Face to face is measured between the two raised flange faces of the valve body.

Reference values transcribed for visualisation. This is not a copy of ISA 75.08.01 and does not replace it. Check every value against the current edition before design, procurement or fabrication.

Values were transcribed from ISA 75.08.01 in millimetres. Inches are converted from the millimetres and rounded to 0.01 in.

Standard: ISA 75.08.01

Values switch where the heading or table title shows mm or in. NPS, DN, bolt counts and bolt sizes stay as they are.

ISA 75.08.01 flanged globe control valve face-to-face, raised face

NPSDNClass 150 (mm)Class 300 (mm)Class 600 (mm)
125184197210
1-1/240222235251
250254267286
2-1/265276292311
380298318337
4100352368394
6150451473508
8200543568610
10250673708752
12300737775819
14350889927972
16400101610571108

Raised-face flanged bodies only; ring-joint bodies are longer. Class 900 and above are left out: the library holds them only as approximate values.

How to read the table

Find the body size and read the length for the flange class. The valve body size is often one or two sizes smaller than the line, with reducers on each side.

Worked example

An NPS 4 Class 300 globe control valve is 368 mm (14.49 in) face to face. A manual globe valve of the same size and class is 14.00 in (356 mm) to ASME B16.10.

Questions

What is the face to face of a 2 inch Class 150 control valve?

254 mm (10.00 in) to ISA 75.08.01.

What is the face to face of a 3 inch Class 300 control valve?

318 mm (12.52 in) to ISA 75.08.01.

Is ISA 75.08.01 the same as IEC 60534-3-1?

IEC 60534-3-1 covers the same subject, flanged globe control valve face-to-face. Use the standard and edition named in your specification.

3D components sized from these values 2