Local control station

Ex e push-button station for a motor or valve, on a galvanised UPN post with base plate and anchors. Start button and a shrouded lock-off stop with padlock, L-O-R selector, moving-iron ammeter with run lamp and a latching E-stop, each with an engraved legend. Rain hood, bottom cable gland with armoured cable cleated down the post, earth stud and tag plate. Rows appear only for the devices switched on.

IEC 60079-0 / -7IEC 60947-5-1IEC 60204-1ISO 13850
Drag to orbit, scroll to zoom
Parameters
– m
– A

Installation

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add local-control-station

Copies electrical/local-control-station.tsx and the shared lib/ into src/components/deck-twin/. Needs three, @react-three/fiber and @react-three/drei. See installation for the manual route.

Usage

import { Canvas } from '@react-three/fiber'
import { OrbitControls } from '@react-three/drei'
import { Stage } from './components/deck-twin/lib/stage'
import { LocalControlStation } from './components/deck-twin/electrical/local-control-station'

export default function Scene() {
  return (
    <Canvas shadows camera={{ position: [8, 5, 9], fov: 35 }}>
      <Stage>
        <LocalControlStation />
      </Stage>
      <OrbitControls makeDefault />
    </Canvas>
  )
}

Props

PropTypeDefaultRange
heightnumber (m)null0.9 – 1.7
enclosure"stainless" | "grp"null
ammeterbooleannull
selectorbooleannull
estopbooleannull
ampsnumber (A)null5 – 600
tagstringnull
...groupposition, rotation, scale…

P&ID

P&ID symbol for local-control-station

Field bubble marked HS (hand switch) beside the motor it starts and stops, joined to it by a dashed electrical signal line; the bubble is often annotated START / STOP or L-O-R.

tag LCSISA HSISA HMSISA 5.1 (hand switch bubble) / IEC 60617

HS bubbles with a horizontal bar are on the console, not in the field. Some P&IDs omit local stations entirely; they then appear only on the electrical layout as a small rectangle at the motor.

Local control station datasheet (IEC 60079-7, IEC 60947-5-1) fields and the props they set
Enclosureenclosure
Ammeterammeter
Selector (L-O-R)selector
Emergency stopestop
Ammeter rangeamps
Tag numbertag

Typical suppliers

R. STAHL · Eaton (Crouse-Hinds CEAG) · Hubbell Killark · Abtech. The geometry is generic and sized from public standards. It is not vendor CAD.

For agents

Machine-readable entry with props, ranges, defaults and ports:

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info local-control-station

Or fetch /r/local-control-station.json, or copy a ready-made instruction:

Add the Deck Twin "Local control station" component to this project. Run `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add local-control-station` (it copies the file and the shared lib into src/components/deck-twin/), then `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info local-control-station` for its props, ranges and ports. Render <LocalControlStation /> inside a React Three Fiber <Canvas shadows>, wrapped in <Stage> from src/components/deck-twin/lib/stage. Set props from my data (metres, NPS in inches, ASME class) and leave the rest at defaults. Install three, @react-three/fiber, @react-three/drei and @types/three if they're missing. Full guide: https://decktwin.com/skill/SKILL.md