Neutral earthing resistor

Outdoor neutral earthing resistor: stacks of stainless grid elements on post insulators with mica plates and series links, in a ventilated 316 stainless enclosure (louvred sides, roof with overhang) on galvanised legs. Neutral entry by a cable box with ring CT and gland or by a roof bushing; LV earth bushing to the earth bar, two enclosure earth bosses, rating plate with the resistance from kV and amps, HV warning and tag. Energy (kV, A, s) sets the number of stacks; open removes a side panel.

IEEE 32IEC 60529 (IP23)ENA / utility NER specs
Drag to orbit, scroll to zoom
Parameters
– A
– s

Installation

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add neutral-earthing-resistor

Copies electrical/neutral-earthing-resistor.tsx and the shared lib/ into src/components/deck-twin/. Needs three, @react-three/fiber and @react-three/drei. See installation for the manual route.

Usage

import { Canvas } from '@react-three/fiber'
import { OrbitControls } from '@react-three/drei'
import { Stage } from './components/deck-twin/lib/stage'
import { NeutralEarthingResistor } from './components/deck-twin/electrical/neutral-earthing-resistor'

export default function Scene() {
  return (
    <Canvas shadows camera={{ position: [8, 5, 9], fov: 35 }}>
      <Stage>
        <NeutralEarthingResistor />
      </Stage>
      <OrbitControls makeDefault />
    </Canvas>
  )
}

Props

PropTypeDefaultRange
kv3.3 | 6.6 | 11 | 13.8 | 33null
ampsnumber (A)null50 – 2000
secondsnumber (s)null5 – 30
entry"cable" | "bushing"null
openbooleannull
tagstringnull
...groupposition, rotation, scale…

P&ID

P&ID symbol for neutral-earthing-resistor

Rectangle (IEC resistor) in the line from the transformer or generator star point down to the earth symbol (three shortening horizontal lines), often with a CT on the neutral.

tag NERIEC 60617 (single-line diagram)

IEC draws resistors as rectangles; ANSI drawings use a zig-zag. A rectangle in a neutral-to-earth connection is an NER; an earthing transformer is a zig-zag winding symbol instead.

Neutral earthing resistor datasheet (IEEE 32) fields and the props they set
System voltagekv
Rated currentamps
Rated timeseconds
Neutral entryentry
Tag numbertag

Typical suppliers

Vishay · Pestech. The geometry is generic and sized from public standards. It is not vendor CAD.

For agents

Machine-readable entry with props, ranges, defaults and ports:

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info neutral-earthing-resistor

Or fetch /r/neutral-earthing-resistor.json, or copy a ready-made instruction:

Add the Deck Twin "Neutral earthing resistor" component to this project. Run `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add neutral-earthing-resistor` (it copies the file and the shared lib into src/components/deck-twin/), then `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info neutral-earthing-resistor` for its props, ranges and ports. Render <NeutralEarthingResistor /> inside a React Three Fiber <Canvas shadows>, wrapped in <Stage> from src/components/deck-twin/lib/stage. Set props from my data (metres, NPS in inches, ASME class) and leave the rest at defaults. Install three, @react-three/fiber, @react-three/drei and @types/three if they're missing. Full guide: https://decktwin.com/skill/SKILL.md