IEC motor frame sizes: shaft height and output

An IEC frame size names a foot-mounted motor by its shaft height H, the distance from the bottom of the feet to the shaft centreline, in millimetres. The letter after it (S, M or L) is the body length, short, medium or long.

EN 50347 gave most frames a rated output for 2, 4 and 6 pole motors, though some frame and pole pairs have none. Makers have long built to this assignment, so motors of the same frame and power from different makers can usually be swapped on the same baseplate. EN 50347 has since been withdrawn, and the assignment now sits in IEC 60072-1.

Hshaft
H is the shaft height, from the underside of the feet to the shaft centreline.

Reference values transcribed for visualisation. This is not a copy of IEC 60072-1 and does not replace it. Check every value against the current edition before design, procurement or fabrication.

Shaft heights are the IEC 60072-1 values. Outputs follow the EN 50347 assignment for totally enclosed fan-cooled cage motors, which the industry has used for many years. EN 50347 was withdrawn in 2022 and IEC 60072-1 now carries the assignment, so check the current edition before relying on a value. Lengths, foot spacing, shaft diameters and masses in the library are typical values and are not shown.

Standard: IEC 60034 / IEC 60072

Frame size, shaft height and rated output

FrameShaft height H (mm)2 pole (kW)4 pole (kW)6 pole (kW)
80M800.75, 1.10.55, 0.750.37, 0.55
90S901.51.10.75
90L902.21.51.1
100L10032.2, 31.5
112M112442.2
132S1325.5, 7.55.53
132M132-7.54, 5.5
160M16011, 15117.5
160L16018.51511
180M1802218.5-
180L180-2215
200L20030, 373018.5, 22
225S225-37-
225M225454530
250M250555537
280S280757545
280M280909055
315S31511011075
315M31513213290

Blank cells: no output is assigned to that frame for that pole count. The table stops at 315M, where the EN 50347 assignment ends. Frame 315L and frames 355 and above are left out because their outputs vary by maker.

How to read the table

Find the rated power in the column for the pole count. At 50 Hz a 2 pole motor runs near 3000 rpm, 4 pole near 1500 rpm and 6 pole near 1000 rpm. The frame on that row is the one usually assigned to that power. Check the current edition of IEC 60072-1 or the data sheet from the maker of a given motor.

Worked example

A 75 kW 4 pole pump motor is frame 280S, so its shaft centre sits 280 mm above its feet. A 15 kW 2 pole motor is frame 160M.

Questions

What does the frame size number mean?

It is the shaft height in millimetres, from the base of the feet to the centre of the shaft. A frame 132 motor has its shaft 132 mm above the feet.

What frame size is a 11 kW 4 pole motor?

Frame 160M, with a shaft height of 160 mm.

What do S, M and L mean in 132S or 160L?

They are body lengths: short, medium and long. Frames with the same number share the shaft height but differ in length and foot spacing.

Are NEMA frame sizes the same as IEC?

No. NEMA frames are a separate North American system in inches, with different shaft heights and mounting dimensions.

3D components sized from these values 5