Centrifugal fan (belt driven)

Single-width single-inlet centrifugal fan for HVAC and process extract: hollow spiral scroll (you see the backward-curved wheel through the bellmouth and down the outlet) with flanged side sheets, inspection door, drain, rotation arrow and nameplate; shaft in two regreasable pillow-block bearings on a pedestal; V-belt drive under a mesh guard; IEC motor on slide rails; steel base frame on open spring isolators; optional flexible duct connectors with companion flanges. Outlet up-blast or top-horizontal; wheel diameter and kW scale the set. Ports are duct flanges (kind utility, NPS = equivalent round duct).

AMCA 99 (arrangement 9)ISO 13349IEC 60034 / 60072
Drag to orbit, scroll to zoom
Parameters
– m
– kW

Installation

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add centrifugal-fan

Copies rotating/centrifugal-fan.tsx and the shared lib/ into src/components/deck-twin/. Needs three, @react-three/fiber and @react-three/drei. See installation for the manual route.

Usage

import { Canvas } from '@react-three/fiber'
import { OrbitControls } from '@react-three/drei'
import { Stage } from './components/deck-twin/lib/stage'
import { CentrifugalFan } from './components/deck-twin/rotating/centrifugal-fan'

export default function Scene() {
  return (
    <Canvas shadows camera={{ position: [8, 5, 9], fov: 35 }}>
      <Stage>
        <CentrifugalFan />
      </Stage>
      <OrbitControls makeDefault />
    </Canvas>
  )
}

Props

PropTypeDefaultRange
wheelDiameternumber (m)null0.3 – 2
kwnumber (kW)null0.75 – 250
outlet"up" | "horizontal"null
flexiblebooleannull
colorstringnull
runningbooleannull
tagstringnull
...groupposition, rotation, scale…

P&ID

P&ID symbol for centrifugal-fan

Circle (scroll) with a wide rectangular outlet duct leaving tangentially and curved blades or a hub drawn inside; inlet through the centre. Axial fans are drawn as a propeller (bow-tie) inside a circle or duct.

tag EFtag SFtag FNISO 10628-2 / PIP PIC001

Looks like a pump but the outlet is a wide duct and it sits on HVAC ducting (often drawn double-line) rather than a pipe. Air cooler fans are part of air-cooled-exchanger.

Fan datasheet (AMCA 99 / ISO 13349) fields and the props they set
Impeller diameterwheelDiameter
Motor rated powerkw
Discharge orientationoutlet
Tag numbertag

Typical suppliers

Novenco · Hartzell. The geometry is generic and sized from public standards. It is not vendor CAD.

For agents

Machine-readable entry with props, ranges, defaults and ports:

$npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info centrifugal-fan

Or fetch /r/centrifugal-fan.json, or copy a ready-made instruction:

Add the Deck Twin "Centrifugal fan (belt driven)" component to this project. Run `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add centrifugal-fan` (it copies the file and the shared lib into src/components/deck-twin/), then `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info centrifugal-fan` for its props, ranges and ports. Render <CentrifugalFan /> inside a React Three Fiber <Canvas shadows>, wrapped in <Stage> from src/components/deck-twin/lib/stage. Set props from my data (metres, NPS in inches, ASME class) and leave the rest at defaults. Install three, @react-three/fiber, @react-three/drei and @types/three if they're missing. Full guide: https://decktwin.com/skill/SKILL.md