Choke and kill lines with HCR valves (BOP side)
Choke and kill lines are the two high-pressure lines that tie into the side outlets of a BOP stack or its drilling spool. When the BOP is closed on a kick, the choke line carries returns from the well to the choke manifold, where the chokes hold back pressure. The kill line lets fluid be pumped into the well below the closed preventer, from the mud pumps. API 16C covers the lines and API Standard 53 covers how they are arranged and tested.
- Model size
- 1.85 × 9.25 × 2.59 m (length × width × height) at the starting settings
- Connections
- 2 ports, NPS 2 to 3, Class 2500
- P&ID tag
- HV, PI
Download this model as a GLB file, with the parameters you set. It opens in Blender, Unity, Unreal, three.js and most 3D viewers. Free for personal use.
Download GLB, free accountInstallation
Installing needs a free account. Run npx decktwin login first.
This command copies wellhead/choke-and-kill-manifold.tsx and the shared lib/ into src/components/deck-twin/. It requires three, @react-three/fiber and @react-three/drei. See installation for manual setup.
Usage
import { Canvas } from '@react-three/fiber'
import { OrbitControls } from '@react-three/drei'
import { Stage } from './components/deck-twin/lib/stage'
import { ChokeAndKillManifold } from './components/deck-twin/wellhead/choke-and-kill-manifold'
export default function Scene() {
return (
<Canvas shadows camera={{ position: [8, 5, 9], fov: 35 }}>
<Stage>
<ChokeAndKillManifold />
</Stage>
<OrbitControls makeDefault />
</Canvas>
)
}
Props
| Prop | Type | Default | Range |
|---|---|---|---|
psi | 5000 | 10000 | 15000 | 10000 | |
stackBore | 11 | 13.625 | 13.625 | |
chokeBore | 3.0625 | 4.0625 | 3.0625 | |
killBore | 2.0625 | 3.0625 | 2.0625 | |
line | "hose" | "swivel" | "hose" | |
connector | "flange" | "hub" | "union" | "flange" | |
killCheck | boolean | true | |
elevation | number (m) | 1.8 | 1.3 to 3 |
reach | number (m) | 4.6 | 3.5 to 7 |
color | string | "#c25b28" | |
tag | string | "CK-100" | |
...group | position, rotation, scale… |
Ports
Flange faces in the component's local coordinate frame, in metres. Origin: centre of the footprint at deck level (y = 0). The plant assembler routes pipework between these ports.
| Id | Label | Position | Direction | Size | Class |
|---|---|---|---|---|---|
choke | Choke line to the choke manifold | 0.000, 0.700, 4.600 | 0, 0, 1 | 3" | 2500 |
kill | Kill line from the kill pump | 0.000, 0.700, -4.600 | 0, 0, -1 | 2" | 2500 |
For agents
The machine-readable entry lists props, ranges, defaults and ports:
You can also fetch /r/choke-and-kill-manifold.json, or copy this instruction:
Add the Deck Twin "Choke and kill lines with HCR valves (BOP side)" component to this project. Run `npx decktwin add choke-and-kill-manifold` (it copies the file and the shared lib into src/components/deck-twin/). If it answers 401 or says to sign in, run `npx decktwin login`, show me the code it prints, wait while I approve it in the browser, then run the add command again. Then run `npx decktwin info choke-and-kill-manifold` for its props, ranges and ports. Render <ChokeAndKillManifold /> inside a React Three Fiber <Canvas shadows>, wrapped in <Stage> from src/components/deck-twin/lib/stage. Set props from my data (metres, NPS in inches, ASME class) and leave the rest at defaults. Install three, @react-three/fiber, @react-three/drei and @types/three if they're missing. Full guide: https://decktwin.com/skill/SKILL.mdWhat the model shows
The BOP end of the choke and kill system: a drilling spool with a valved choke outlet (+Z) and kill outlet (-Z), and the lines that leave it. Each outlet has a manual gate valve next to the spool and a hydraulic HCR gate valve outboard of it. Control hoses run from the HCR valves to a bulkhead plate. The kill side can add a check valve (killCheck). connector joins each line to its outer valve with an API 6A flange or a clamp hub, or a hammer union where the project allows one. line sets the line type: flexible armoured hoses with end fittings, or articulated steel lines with swivel joints. Both run down to terminal spools on deck stands. The spool sits on a spacer spool that stands in for the lower stack, and its studded top is left open. Ports are the API faces of the two terminals. Their rating is a placeholder ASME B16.5 class for the plant file (2500 for 10K and 15K, 1500 for 5K), not an equivalent pressure rating. Flange and valve dimensions are typical API 6A values.
Questions
What is an HCR valve?
HCR is usually said to stand for high closing ratio. It is a hydraulically operated gate valve on a BOP side outlet, opened and closed from the BOP control system. On a rig lined up for a hard shut-in, the choke line HCR is kept closed while drilling and the manual valve next to the stack is kept open, so the line can be opened from the driller's panel after the BOP is closed. The line-up follows the operator's well control procedure. In this model the HCR is the outer gate valve on each outlet, with the yellow actuator.
What is a choke and kill connector?
It is the connection that joins a choke or kill line to the stack. On a surface stack this is an API 6A flange or a clamp hub. API 16C also covers union connections for choke and kill assemblies, and connector: union draws a hammer union for those cases. API Standard 53 calls for flanged, welded or hubbed connections on parts under well pressure at 3,000 psi and above, so check a union against the project rules. On a subsea stack the choke and kill lines run up the drilling riser as auxiliary lines, and stab connectors join them at each riser joint and at the lower marine riser package. The subsea stab connectors are not modelled.
What is a choke and kill swivel joint system?
It is an articulated steel line: straight pipe sections joined by swivel joints, so the line can follow movement between the BOP and the rig. line: swivel draws one with two long-radius elbows between swivel joints. line: hose draws the other common choice, a flexible choke and kill line with end fittings. API 16C covers both types.
How do I use it with the BOP stack and the choke manifold?
The BOP stack already has its own choke and kill valves on its drilling spool. Use this component when you need the lines themselves, a different connector, or a spool on its own. Connect the choke port to the inlet of the choke manifold and the kill port to the kill pump line. Set psi, chokeBore and killBore to match the stack, and elevation to the height of the spool outlets.
P&ID
A drilling spool in the BOP stack with a line leaving each side. Each line has a manual gate valve next to the spool and a hydraulic valve (a bow-tie with an actuator box, marked HCR) outboard of it. The kill side often shows a check valve. The choke line runs on to the choke manifold and the kill line to the kill pump.
This is the BOP end of the choke and kill system. The manifold with the chokes is choke-manifold, and bop-stack already draws its own outlet valves. Only on drilling or well-control schematics.
psistackBorechokeBorekillBorelineconnectorkillChecktagTypical suppliers
SLB (Cameron), TechnipFMC (Chiksan, Coflexip). The geometry is generic and sized to public standards. It is not vendor CAD.