Cooling tower (induced draft, counterflow)
Onshore mechanical-draft counterflow cooling tower in a row of cells: concrete cold-water basin with outlet sump, FRP-clad casing on a column frame, louvred air inlets on the long sides, fan deck with handrails, velocity-recovery fan stacks, axial fans on right-angle gearboxes driven through a drive shaft by motors outside the stacks, vibration switches and oil-level lines, hot-water riser and distribution header with a valve per cell, make-up and overflow, and caged ladders with a rest platform. Fans spin while running.
Installation
Copies thermal/cooling-tower.tsx and the shared lib/ into src/components/deck-twin/. Needs three, @react-three/fiber and @react-three/drei. See installation for the manual route.
Usage
import { Canvas } from '@react-three/fiber'
import { OrbitControls } from '@react-three/drei'
import { Stage } from './components/deck-twin/lib/stage'
import { CoolingTower } from './components/deck-twin/thermal/cooling-tower'
export default function Scene() {
return (
<Canvas shadows camera={{ position: [8, 5, 9], fov: 35 }}>
<Stage>
<CoolingTower />
</Stage>
<OrbitControls makeDefault />
</Canvas>
)
}
Props
| Prop | Type | Default | Range |
|---|---|---|---|
cells | number | null | 1 – 8 |
cellSize | number (m) | null | 4 – 18 |
deckHeight | number (m) | null | 6 – 18 |
inletHeight | number (m) | null | 1.5 – 6 |
kw | number (kW) | null | 15 – 250 |
inletNps | number (NPS, in) | null | |
outletNps | number (NPS, in) | null | |
running | boolean | null | |
tag | string | null | |
...group | position, rotation, scale… |
P&ID
A box (or tapering hyperbolic outline for natural draft) with a fan stack on top (propeller in a short cylinder), the hot-water distribution near the top, crossed lines for the fill, air inlets low on the sides and the cold-water basin at the bottom.
The fan on top plus fill and basin tell it from an air-cooled exchanger (tube bundle, no water basin). Onshore only.
cellscellSizedeckHeightinletHeightkwinletNpsoutletNpstagTypical suppliers
SPX Cooling Tech (Marley) · Hamon · Enexio · EVAPCO · Baltimore Aircoil. The geometry is generic and sized from public standards. It is not vendor CAD.
For agents
Machine-readable entry with props, ranges, defaults and ports:
Or fetch /r/cooling-tower.json, or copy a ready-made instruction:
Add the Deck Twin "Cooling tower (induced draft, counterflow)" component to this project. Run `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz add cooling-tower` (it copies the file and the shared lib into src/components/deck-twin/), then `npx -y https://decktwin.com/cli/deck-twin-0.2.2.tgz info cooling-tower` for its props, ranges and ports. Render <CoolingTower /> inside a React Three Fiber <Canvas shadows>, wrapped in <Stage> from src/components/deck-twin/lib/stage. Set props from my data (metres, NPS in inches, ASME class) and leave the rest at defaults. Install three, @react-three/fiber, @react-three/drei and @types/three if they're missing. Full guide: https://decktwin.com/skill/SKILL.md