ASME B36.10 vs B36.19
Carbon steel pipe schedules and stainless steel pipe schedules
The short answer
ASME B36.10 sets the dimensions of welded and seamless wrought steel pipe, mainly carbon and low-alloy steel. ASME B36.19 sets the dimensions of welded and seamless wrought stainless steel pipe. Editions up to 2018 carried an M: B36.10M and B36.19M. The outside diameters are the same in both, so fittings and flanges fit either. B36.19 has its own wall schedules with an S suffix: 5S, 10S, 40S and 80S. The last three match Schedules 10, 40 and 80 over part of the size range, but not at every size.
Side by side
| ASME B36.10 | ASME B36.19 | |
|---|---|---|
| What it is | Welded and seamless wrought steel pipe | Welded and seamless wrought stainless steel pipe |
| Issued by | ASME | ASME |
| Materials | Mainly carbon and low-alloy steel | Stainless steel |
| Outside diameter | Fixed for each NPS | The same as B36.10 for each NPS |
| Wall designations | Schedule numbers such as 10, 40, 80 and 160, and the weights STD, XS and XXS | Schedules 5S, 10S, 40S and 80S |
| Typical material specifications | ASTM A106, ASTM A333 and API 5L | ASTM A312 |
| On oil and gas facilities | Most hydrocarbon process, flare and utility lines | Stainless utility, instrument air, chemical injection and some water systems |
| How they relate | The base dimensional standard for steel pipe | A companion standard with the same diameters and its own stainless walls |
Both set dimensions only. Material, manufacture and testing come from the material specification, and pressure design from the piping code.
When each one applies
Carbon steel and low-alloy steel pipe is dimensioned to B36.10. Stainless pipe is dimensioned to B36.19, and the piping class names the schedule for each size.
Neither standard says how thick the wall must be for a given pressure. The designer works out the required wall to the piping code, such as ASME B31.3, and then picks the next schedule up from these tables.
How they are used together
A plant usually has both. A carbon steel class might use Schedule 80 for small bore and STD for large bore, while a stainless class for instrument air or chemical injection uses 10S or 40S. Because the outside diameters match, the same flange and fitting standards serve both classes, with the fitting wall matched to the pipe.
Common confusions
Schedule 40S and Schedule 40 match up to NPS 10. From NPS 12 upward Schedule 40S stays at 9.53 mm, while Schedule 40 gets thicker. Schedule 80S and Schedule 80 part company in the same way above NPS 8.
Schedule 10S is thinner than Schedule 10 from NPS 14 to NPS 22, so a 10S wall cannot be read off the B36.10 table.
STD and XS are weights rather than schedules. STD matches Schedule 40 only up to NPS 10, and XS matches Schedule 80 only up to NPS 8.
NPS is a size name, not a measured diameter. Up to NPS 12 the outside diameter is larger than the NPS, and from NPS 14 upward it equals the NPS in inches.
How the choice shows up on a specification
A line list or bill of materials gives the size, the wall and the material together, for example 6 in Sch 40 to ASTM A106 Grade B, or 2 in Sch 10S to ASTM A312 TP316L. The S suffix tells the reader the wall is a B36.19 wall.
Questions
What is the difference between ASME B36.10 and B36.19?
B36.10 covers carbon and alloy steel pipe, and B36.19 covers stainless steel pipe. The outside diameters are the same. B36.19 has its own S schedules, 5S, 10S, 40S and 80S, including light walls that corrosion-resistant pipe can use. See ASME B36.10 and B36.19.
Is Schedule 40S the same as Schedule 40?
Up to NPS 10 the wall thickness is the same. From NPS 12 upward, Schedule 40S stays at 9.53 mm while Schedule 40 keeps getting thicker.
Why does stainless pipe have thinner schedules?
Stainless pipe resists corrosion, so it needs little or no corrosion allowance, and it is costly. Light walls such as 5S and 10S save weight and cost where the pressure allows.
What happened to the M in B36.10M and B36.19M?
Editions up to 2018 were published as B36.10M and B36.19M. ASME has published them as B36.10 and B36.19 since the 2022 editions. Older drawings and specifications still use the M names.
This page explains two standards in plain words. It is not a substitute for the standards themselves, and project specifications often add to both. Deck Twin uses these standards as reference values for visualisation. Check the current edition of each standard before using any value for design, procurement or fabrication.