Fire, gas & safety 3D models
F&G detectors, manual call points, deluge systems, fire monitors, safety showers and lifesaving equipment. 29 parametric three.js components, each a single file sized to its governing standard, with ports for pipe connections. The geometry is generic, not vendor CAD.
Acoustic (ultrasonic) gas leak detector
Ultrasonic (acoustic) gas leak detector that hears the 25–100 kHz noise of a pressurised gas leak.
Alarm beacon and sounder
Ex d status or general-alarm (GA/PAGA) beacon with a guarded coloured lens on a shelf bracket and an optional horn sounder on a stainless U-bracket below.
Aspirating smoke detector
Very early warning aspirating smoke detector for E-houses, LERs and switchrooms.
Breathing apparatus cabinet
GRP storage cabinet for self-contained breathing apparatus, hollow with a gel-coat lining, moulded front flange, door seal, left-hand piano hinge, toggle latches and pull handle; the door carries a blue mandatory respiratory-protection sign and the tag.
Deluge nozzle / sprinkler head
Water-spray discharge head, a few centimetres across, screwed by its ½" NPT thread into a reducing coupling on a short threaded drop nipple.
Deluge valve skid
Deluge valve set in firewater red, with a clapper/diaphragm-type deluge valve and bolted cover between locked-open OS&Y isolation valves.
Emergency telephone
Hazardous-area emergency telephone: Ex d cast body with bolted cover, handset on its hook with perforated ear and mouth caps, armoured stainless cord, keypad, red emergency call button, ringer grille, gland and stopping plug.
Escape route and muster sign
Escape-route signage to ISO 7010: emergency exit E001 (left hand) or E002 (right hand) with a supplementary direction arrow, or evacuation assembly point E007 (square, larger), each over a legend band.
Ex emergency luminaire
Hazardous-area emergency and escape-route luminaire with integral 3 h battery.
Fire blanket
Wall-mounted fire blanket in a rigid red quick-release container: back plate, shell with printed FIRE BLANKET instructions and pictogram, open bottom slot showing the folded blanket, two black pull tapes with finger loops.
Fire extinguishers
EN 3 fire extinguishers with red bodies and agent colour zones: dry powder blue, CO2 black with a discharge horn, and foam cream.
Fire hose reel
EN 671-1 swinging fire hose reel with 25 mm semi-rigid hose wound on a drum with a spoked front cheek.
Fire monitor
Fixed firewater monitor on a red riser, with a slewing turret, elevating gooseneck and fog nozzle.
First-aid station
First-aid point: hollow green GRP cabinet with gel-coat lining, hinged door with a large white cross, FIRST AID legend, latches, handle and tag.
Heat detector
Ex d fixed-temperature / rate-of-rise heat detector with a red flameproof head and a finned sensing element inside a guard cage.
Hydrogen gas detector
Fixed hydrogen detector for battery and UPS rooms, electrolysers and fuel-cell enclosures.
IR3 flame detector
Triple-IR flame detector in a red Ex d housing on a stainless ball-swivel mount.
Life jacket box (lifejacket storage)
Deck lifejacket chest at muster stations and lifeboat embarkation points.
Lifebuoy station
SOLAS lifebuoy (730 mm OD, 440 mm ID, 2.5 to 4 kg class) in orange, with four retro-reflective bands, a festooned grab line and a stencilled name.
Manual call point
Ex d manual alarm call point with a break-glass window, hinged lift flap, key-operated test facility, captive cover screws and status LED. It has one gland and two stopping plugs.
Open-path gas detector
Line-of-sight IR gas detector pair with transmitter and receiver heads on pan/tilt mounts, facing each other along X. Each head has a stainless barrel, yellow hood, lens window and alignment sight.
PA/GA horn loudspeaker
Hazardous-area public address and general alarm horn loudspeaker.
Pillar fire hydrant
Dry-barrel pillar hydrant on an underground firewater main.
Point gas detector (flammable gas)
Point gas detector for fire and gas systems, available as an infrared or catalytic type.
Reflective beam smoke detector
Reflective optical beam smoke detector for large open volumes such as warehouses, turbine halls and module roofs.
Safety shower and eyewash
Combination emergency shower and eyewash in safety green.
Smoke detector
Optical (photoelectric) smoke detector for enclosed rooms such as the LER, CCR and accommodation.
Toxic gas detector (H2S, CO)
Electrochemical toxic gas transmitter: cast Ex d enclosure with screwed window cover, ppm display, status LED and magnetic-key calibration targets, sensor pointing down under a hollow weather cap with calibration nozzle and flared splash guard.
Windsock
Helideck windsock on a tilting galvanised mast.