Fire, gas & safety 3D models

F&G detectors, manual call points, deluge systems, fire monitors, safety showers and lifesaving equipment. 29 parametric three.js components, each a single file sized to its governing standard, with ports for pipe connections. The geometry is generic, not vendor CAD.

IEC 60079-1IEC 60079-11ISA TR84.00.07EN 54-23EN 54-3EN 54-20NFPA 72BS 5839-1EN 137ISO 7010SOLAS FSS Code ch. 3NFPA 15
Acoustic (ultrasonic) gas leak detector 3D model

Acoustic (ultrasonic) gas leak detector

Ultrasonic (acoustic) gas leak detector that hears the 25–100 kHz noise of a pressurised gas leak.

Alarm beacon and sounder 3D model

Alarm beacon and sounder

Ex d status or general-alarm (GA/PAGA) beacon with a guarded coloured lens on a shelf bracket and an optional horn sounder on a stainless U-bracket below.

Aspirating smoke detector 3D model

Aspirating smoke detector

Very early warning aspirating smoke detector for E-houses, LERs and switchrooms.

Breathing apparatus cabinet 3D model

Breathing apparatus cabinet

GRP storage cabinet for self-contained breathing apparatus, hollow with a gel-coat lining, moulded front flange, door seal, left-hand piano hinge, toggle latches and pull handle; the door carries a blue mandatory respiratory-protection sign and the tag.

Deluge nozzle / sprinkler head 3D model

Deluge nozzle / sprinkler head

Water-spray discharge head, a few centimetres across, screwed by its ½" NPT thread into a reducing coupling on a short threaded drop nipple.

Deluge valve skid 3D model

Deluge valve skid

Deluge valve set in firewater red, with a clapper/diaphragm-type deluge valve and bolted cover between locked-open OS&Y isolation valves.

Emergency telephone 3D model

Emergency telephone

Hazardous-area emergency telephone: Ex d cast body with bolted cover, handset on its hook with perforated ear and mouth caps, armoured stainless cord, keypad, red emergency call button, ringer grille, gland and stopping plug.

Escape route and muster sign 3D model

Escape route and muster sign

Escape-route signage to ISO 7010: emergency exit E001 (left hand) or E002 (right hand) with a supplementary direction arrow, or evacuation assembly point E007 (square, larger), each over a legend band.

Ex emergency luminaire 3D model

Ex emergency luminaire

Hazardous-area emergency and escape-route luminaire with integral 3 h battery.

Fire blanket 3D model

Fire blanket

Wall-mounted fire blanket in a rigid red quick-release container: back plate, shell with printed FIRE BLANKET instructions and pictogram, open bottom slot showing the folded blanket, two black pull tapes with finger loops.

Fire extinguishers 3D model

Fire extinguishers

EN 3 fire extinguishers with red bodies and agent colour zones: dry powder blue, CO2 black with a discharge horn, and foam cream.

Fire hose reel 3D model

Fire hose reel

EN 671-1 swinging fire hose reel with 25 mm semi-rigid hose wound on a drum with a spoked front cheek.

Fire monitor 3D model

Fire monitor

Fixed firewater monitor on a red riser, with a slewing turret, elevating gooseneck and fog nozzle.

First-aid station 3D model

First-aid station

First-aid point: hollow green GRP cabinet with gel-coat lining, hinged door with a large white cross, FIRST AID legend, latches, handle and tag.

Heat detector 3D model

Heat detector

Ex d fixed-temperature / rate-of-rise heat detector with a red flameproof head and a finned sensing element inside a guard cage.

Hydrogen gas detector 3D model

Hydrogen gas detector

Fixed hydrogen detector for battery and UPS rooms, electrolysers and fuel-cell enclosures.

IR3 flame detector 3D model

IR3 flame detector

Triple-IR flame detector in a red Ex d housing on a stainless ball-swivel mount.

Life jacket box (lifejacket storage) 3D model

Life jacket box (lifejacket storage)

Deck lifejacket chest at muster stations and lifeboat embarkation points.

Lifebuoy station 3D model

Lifebuoy station

SOLAS lifebuoy (730 mm OD, 440 mm ID, 2.5 to 4 kg class) in orange, with four retro-reflective bands, a festooned grab line and a stencilled name.

Manual call point 3D model

Manual call point

Ex d manual alarm call point with a break-glass window, hinged lift flap, key-operated test facility, captive cover screws and status LED. It has one gland and two stopping plugs.

Open-path gas detector 3D model

Open-path gas detector

Line-of-sight IR gas detector pair with transmitter and receiver heads on pan/tilt mounts, facing each other along X. Each head has a stainless barrel, yellow hood, lens window and alignment sight.

PA/GA horn loudspeaker 3D model

PA/GA horn loudspeaker

Hazardous-area public address and general alarm horn loudspeaker.

Pillar fire hydrant 3D model

Pillar fire hydrant

Dry-barrel pillar hydrant on an underground firewater main.

Point gas detector (flammable gas) 3D model

Point gas detector (flammable gas)

Point gas detector for fire and gas systems, available as an infrared or catalytic type.

Reflective beam smoke detector 3D model

Reflective beam smoke detector

Reflective optical beam smoke detector for large open volumes such as warehouses, turbine halls and module roofs.

Safety shower and eyewash 3D model

Safety shower and eyewash

Combination emergency shower and eyewash in safety green.

Smoke detector 3D model

Smoke detector

Optical (photoelectric) smoke detector for enclosed rooms such as the LER, CCR and accommodation.

Toxic gas detector (H2S, CO) 3D model

Toxic gas detector (H2S, CO)

Electrochemical toxic gas transmitter: cast Ex d enclosure with screwed window cover, ppm display, status LED and magnetic-key calibration targets, sensor pointing down under a hollow weather cap with calibration nozzle and flared splash guard.

Windsock 3D model

Windsock

Helideck windsock on a tilting galvanised mast.

Other categories