Waste injection skid (cuttings re-injection)
A waste injection skid, or cuttings re-injection (CRI) package, grinds drilled cuttings and other drilling waste into a fine slurry and pumps it down a dedicated well into a disposal formation. That avoids shipping cuttings to shore or discharging them at sea, and supports zero-discharge drilling offshore and on land.
Download this model as a GLB file, with the parameters you set. It opens in Blender, Unity, Unreal, three.js and most 3D viewers. Free for personal use.
Download GLB, free accountInstallation
Installing needs a free account. Run npx decktwin login first.
This command copies packages/waste-injection-skid.tsx and the shared lib/ into src/components/deck-twin/. It requires three, @react-three/fiber and @react-three/drei. See installation for manual setup.
Usage
import { Canvas } from '@react-three/fiber'
import { OrbitControls } from '@react-three/drei'
import { Stage } from './components/deck-twin/lib/stage'
import { WasteInjectionSkid } from './components/deck-twin/packages/waste-injection-skid'
export default function Scene() {
return (
<Canvas shadows camera={{ position: [8, 5, 9], fov: 35 }}>
<Stage>
<WasteInjectionSkid />
</Stage>
<OrbitControls makeDefault />
</Canvas>
)
}
Props
| Prop | Type | Default | Range |
|---|---|---|---|
tanks | number | 2 | 1 to 2 |
tankVolume | number (m3) | 8 | 4 to 20 |
injectionKw | number (kW) | 450 | 150 to 1000 |
inletNps | number (NPS, in) | 6 | |
dischargeNps | number (NPS, in) | 3 | |
dischargeRating | 150 | 300 | 600 | 900 | 1500 | 2500 | 1500 | |
running | boolean | true | |
tag | string | "X-4800" | |
...group | position, rotation, scale… |
Ports
Flange faces in the component's local coordinate frame, in metres. Origin: centre of the footprint at deck level (y = 0). The plant assembler routes pipework between these ports.
| Id | Label | Position | Direction | Size | Class |
|---|---|---|---|---|---|
inlet | Cuttings slurry inlet | -6.264, 2.497, -0.870 | -1, 0, 0 | 6" | 150 |
water | Wash / seawater | -6.334, 0.718, 0.372 | -1, 0, 0 | 3" | 150 |
discharge | HP injection discharge | 6.334, 1.396, 1.692 | 1, 0, 0 | 3" | 1500 |
drain | Drain | -6.334, 0.398, 0.623 | -1, 0, 0 | 3" | 150 |
For agents
The machine-readable entry lists props, ranges, defaults and ports:
You can also fetch /r/waste-injection-skid.json, or copy this instruction:
Add the Deck Twin "Waste injection skid (cuttings re-injection)" component to this project. Run `npx decktwin add waste-injection-skid` (it copies the file and the shared lib into src/components/deck-twin/). If it answers 401 or says to sign in, run `npx decktwin login`, show me the code it prints, wait while I approve it in the browser, then run the add command again. Then run `npx decktwin info waste-injection-skid` for its props, ranges and ports. Render <WasteInjectionSkid /> inside a React Three Fiber <Canvas shadows>, wrapped in <Stage> from src/components/deck-twin/lib/stage. Set props from my data (metres, NPS in inches, ASME class) and leave the rest at defaults. Install three, @react-three/fiber, @react-three/drei and @types/three if they're missing. Full guide: https://decktwin.com/skill/SKILL.mdWhat the model shows
Cuttings re-injection package that turns ground drill cuttings and slops into a slurry and pumps it into a disposal formation. Agitated slurry tanks on skirts carry a roof walkway with a caged ladder and a classification shaker; grinding pumps shear the coarse tank over the shaker, and a charge pump feeds an API 674 triplex plunger pump (the reciprocating-pump component). The HP manifold has pressure transmitters, a gauge, a PSV to the drain header, an actuated ESD valve and a check valve to the wellhead flange. tanks (1 or 2) and tankVolume set the tank size and skid length, injectionKw sizes the triplex, and dischargeNps / dischargeRating set the HP line.
Questions
What is on a CRI package?
Slurry conditioning tanks with agitators, grinding pumps that shear the cuttings, a classification shaker that returns oversize particles for more grinding, a charge pump, and a high-pressure plunger pump that injects the slurry. The discharge has a pressure transmitter, a relief valve and an ESD valve before the injection wellhead. This model reuses the API 674 plunger pump and centrifugal pump components.
How is it sized?
By the cuttings rate from the drilling programme and by the injection pressure needed to fracture and hold the disposal formation, which sets the triplex power and the discharge class. Set tanks, tankVolume, injectionKw, dischargeNps and dischargeRating (often class 1500 or 2500) to match a design.
Who supplies cuttings re-injection systems?
Service companies supply most CRI packages along with the injection engineering, among them Halliburton (Baroid), SLB (M-I SWACO) and NOV. The model is a generic arrangement, not any company's design.
P&ID
Dash-dot package boundary with one or two open agitated tanks (agitator motor on top, shaft and impeller drawn into the tank), a classification shaker between or over them, grinding centrifugal pumps recirculating each tank, a charge pump, and a reciprocating (triplex) pump symbol discharging into a high-pressure line with an ESD valve (XV), PSV and pressure transmitters to the injection well.
Often drawn as a single vendor package box with only the cuttings inlet, wash water, drain and HP injection connections. The HP line downstream of the skid goes to the CRI wellhead or a dedicated annulus; injection pressure and volume are logged per batch.
tankstankVolumeinjectionKwinletNpsdischargeNpsdischargeRatingtagTypical suppliers
Halliburton (Baroid), SLB (M-I SWACO), NOV. The geometry is generic and sized to public standards. It is not vendor CAD.