ISO 14122
Permanent means of access to machinery
ISO 14122 covers fixed access to machinery: platforms, walkways, stairs, guardrails and ladders. How it applies offshore, and the matching 3D parts.
Scope
ISO 14122 is a machinery safety standard in four parts. Part 1 sets how to choose between a ramp, a stair, a stepladder and a fixed ladder. Part 2 covers working platforms and walkways. Part 3 covers stairs, stepladders and guardrails. Part 4 covers fixed ladders, including safety cages and rest platforms. It is published in Europe as EN ISO 14122.
On oil and gas facilities it is the usual reference for the access steel around equipment: valve and instrument platforms on vessels, stairs between decks, caged ladders on columns and stacks, and walkways along pipe racks. Offshore operators often combine it with company specifications and NORSOK requirements.
It does not cover structural design of the steel, lifts and hoists, or temporary access such as scaffolding. Loads and dimensions must be taken from the current edition and the project specification.
The four parts of ISO 14122
Each part covers one kind of fixed access. Part 1 is read first, because it decides which kind is allowed.
| Part | Covers | What you use it for |
|---|---|---|
| ISO 14122-1 | Choice of fixed means and general requirements of access | Deciding between a walkway, a ramp, a stair, a stepladder and a fixed ladder |
| ISO 14122-2 | Working platforms and walkways | Clear width, headroom, floor surface and openings |
| ISO 14122-3 | Stairs, stepladders and guard-rails | Stair pitch, risers and goings, landings, handrails and guardrails |
| ISO 14122-4 | Fixed ladders | Rungs, clearances, cages or fall arrest, and rest platforms |
The current editions of all four parts date from 2016 and were last confirmed by ISO in 2021. ISO is drafting a revision that would merge them into one document. In Europe they are published as EN ISO 14122 and in the UK as BS EN ISO 14122.
Choosing the type of access
Part 1 sets an order of preference, to be followed as far as practicable. Access directly from ground or floor level comes first. Where a change of level cannot be avoided, a ramp or a stair comes next. A stepladder or a fixed ladder comes last, and needs a good reason, such as a stair not being practicable. Lifts and other powered access are outside the series.
The choice takes account of ergonomics and the risk assessment for the machine. Things that usually count are how often the route is used, whether tools or parts are carried, how many people use it and how they would be rescued.
Commonly quoted dimensions
The figures below are the ones quoted most often from the 2016 editions. They are for orientation only.
| Item | Commonly quoted value |
|---|---|
| Guardrail needed | Where a person could fall more than 500 mm |
| Guardrail top rail height | At least 1100 mm |
| Toe plate height | At least 100 mm |
| Gap between rails | Not more than 500 mm |
| Walkway clear width | At least 800 mm, or 1000 mm where several people often pass. Can drop to 600 mm for occasional use |
| Headroom over walkways | At least 2100 mm |
| Stair pitch | 30° to 38° recommended |
| Fixed ladder fall protection | Needed where the fall height is 3000 mm or more |
These values are widely quoted from ISO 14122-1 to -4. They are not a copy of the standard, and each has conditions and exceptions. Take design values from the current edition and the project specification.
Key concepts
- Choice of access
- Part 1 sets an order of preference. Access from ground or floor level comes first, then a ramp or a stair, and a stepladder or a fixed ladder comes last. The angle of the route sets the type: ramps up to 20°, stairs above 20° up to 45°, stepladders above 45° up to 75° and fixed ladders above 75°.
- Guardrails
- A guardrail has a top rail, at least one knee rail and a toe plate. A top rail height of 1.1 m is the widely used value. Guardrails are needed where the fall height or the edge condition makes a fall possible.
- Stairs
- A stair is defined by its pitch, riser height, going and clear width. The going and riser are related by a step formula so that the stair is comfortable to climb. Long flights need intermediate landings.
- Fixed ladders
- Part 4 sets rung spacing, ladder width and the clearances behind and beside the ladder. Above a certain climb a safety cage or a fall arrest system is needed, and long climbs are broken into flights with rest platforms.
- Walkways and platforms
- Part 2 sets minimum clear widths and headroom for walkways and working platforms. Floor surfaces must be slip-resistant, which on facilities usually means open steel or FRP grating.
- Gates and openings
- Openings in guardrails at ladder heads must be protected, usually by a self-closing gate or an offset entry. The gate must not open outward over the drop.
Questions
What is ISO 14122?
ISO 14122 is the machinery safety standard for permanent means of access: working platforms, walkways, stairs, stepladders, guardrails and fixed ladders. It has four parts and applies to access that is fixed to a machine or to the structure around it.
What is EN ISO 14122?
EN ISO 14122 is the same standard adopted as a European standard. It is harmonised under the EU Machinery Directive 2006/42/EC, so following it is the usual way to show that the access on a machine meets the essential safety requirements. BS EN ISO 14122 is the UK publication.
What guardrail height does ISO 14122 require?
The commonly quoted value from ISO 14122-3 is a top rail at least 1100 mm above the walking surface, with a knee rail and a toe plate at least 100 mm high. A guardrail is needed where a person could fall more than 500 mm.
When does a fixed ladder need a cage?
ISO 14122-4 asks for fall protection where the fall height is 3000 mm or more. The standard names a safety cage as the preferred choice, with a guided fall arrester on a rigid anchorage line as the alternative, and the two are not combined on one ladder. Long climbs are split into flights with rest platforms.
Does ISO 14122 apply to buildings?
Only where the access is there to reach a machine. It applies to machinery and to the access that serves it, and other stairs and guardrails in a building follow building regulations. On process plants and offshore facilities it is widely used for access steel around equipment, often with NORSOK standards or company specifications.
In Deck Twin
The ACCESS table in lib/standards/access.ts holds the access values used across the library, such as the 1.1 m handrail height, and stairFlight(rise, angleDeg) works out an even set of risers and goings for a given rise. The stair, ladder, handrail, access platform and grating panel components follow it, and so do the platforms and caged ladders on the column, flare stack, vent boom and storage tank. The values are typical design values for visualisation, not for design or fabrication.
import { stairFlight, ACCESS } from './components/deck-twin/lib/standards'
stairFlight(4) // { steps: 22, riser: 0.182, going: 0.233, run: 4.887, angleDeg: 38 } (rounded)
ACCESS.handrail.height // 1.1Deck Twin uses these standards as reference values for visualisation. Check the current edition of each standard before using any value for design, procurement or fabrication.