Flowmeter and field instrument P&ID symbols
A primary element is the part that touches the process: the orifice plate, the thermowell, the radar horn or the float. On a P&ID it is drawn on the line or vessel and joined to a tag bubble, such as FE, FT, LT or TT. The drawing on the pipe gives the measuring principle, and the bubble gives the variable and function.
30 symbols. Company legends vary, so the legend sheet of the drawing you are reading comes first.
How to read these symbols
Flow elements
Differential pressure meters change the pipe outline: an orifice plate is a bar with a gap between flanges, a venturi narrows and widens, and a flow nozzle curves inward. Other meters vary more between legends. This library draws them as an in-line box with a mark inside: M for magnetic, a bluff body and wavy trail for vortex, a rotor for turbine, a looped tube for Coriolis and two meshing rotors for positive displacement. An ultrasonic meter shows two transducers with a dashed diagonal path between them.
Level
A gauge glass is a narrow rectangle on two nozzles, and a magnetic gauge adds a column of indicator flaps. A displacer hangs inside an external cage. A dp level transmitter has two impulse lines, one to a low nozzle and one to a high nozzle. Radar is a cone on a top nozzle with wave arcs, and guided wave radar has a rod down into the liquid. A nuclear gauge has a source on one side of the vessel and a detector on the other.
Pressure and temperature
A PI or PT bubble on a thin impulse line is a pressure gauge or transmitter, often with a root valve. A PDT has two impulse lines across a filter, exchanger or column section. Here a thermowell is a U-shaped pocket dipping into the line, with TE, TT or TI above it. A capillary with × marks to a flat seal on the nozzle is a remote diaphragm seal.
Switches and analysers
Switch bubbles end in S and a limit, such as PSH or LSLL. An AT or AE bubble on a probe is an analyser, with the measured component written beside it, such as H2S, O2 or OIW. The letters follow ISA 5.1.
All 30 symbols
Download the legend sheet (SVG)Whole legend (SVG)
How each symbol is drawn
| Symbol | Drawn as | Tags |
|---|---|---|
| Orifice plate flow element with dp transmitter | An orifice plate between a flange pair on the line (a bar across the pipe with a gap in the middle for the bore), with two impulse lines from the flange taps up to an FT bubble. | FE, FT, FIT |
| Venturi tube | The line narrows through a short throat and widens again (converging and diverging lines either side of the pipe), with an FE bubble above. | FE |
| Flow nozzle | A flange pair with two curved lines inside the pipe converging downstream (the nozzle profile), and an FE bubble. | FE |
| Pitot tube | A probe from an FE bubble into the pipe, bent into an L whose open end faces upstream. | FE |
| Averaging pitot (multiport probe) | A bar across the full pipe bore with several small holes (dots) on its upstream face, under an FE bubble. | FE |
| Electromagnetic flowmeter | An in-line rectangle on the pipe with "M" inside, under an FT/FIT bubble. | FE, FT, FIT |
| Vortex flowmeter | An in-line rectangle with a small triangle (the bluff body) and a wavy vortex trail behind it, under an FT bubble. | FE, FT, FIT |
| Turbine flowmeter | An in-line rectangle with a small rotor (a hub with blades) inside, under an FT or FQ bubble. | FE, FT, FQ |
| Positive displacement flowmeter | An in-line rectangle with two small touching ovals or circles (meshing rotors) inside, often with an FQ (totaliser) bubble. | FE, FQ, FQI |
| Ultrasonic flowmeter | Two small transducers on opposite sides of the pipe, offset along it, with a dashed diagonal sound path between them, under an FT bubble. | FE, FT, FIT, FQ |
| Coriolis mass flowmeter | An in-line box on the pipe with a looped (U-shaped) tube inside, under an FT bubble. | FE, FT, FIT, FQ |
| Variable-area flowmeter (rotameter) | A vertical tapered tube, wider at the top, with a small float inside; the flow enters at the bottom and leaves at the top. | FI, FG |
| Thermowell with temperature element / transmitter | A U-shaped pocket dipping into the line (the thermowell), with a line up to a TT or TE bubble. | TW, TE, TT, TIT |
| Local temperature gauge | A thermowell (U-shaped pocket in the line) with a TI bubble on it. | TI, TG |
| Local pressure gauge | A PI (or PG) bubble on a thin impulse line from the pipe, often with a small root or isolation valve on the impulse line. | PI, PG |
| Pressure transmitter | A PT (or PIT) bubble on a thin impulse line from the pipe or vessel, with an electric (dashed) signal leaving to the DCS. | PT, PIT |
| Differential pressure transmitter (PDT) | A PDT bubble with two impulse lines: one to each side of a filter, strainer, exchanger or column section. | PDT, PDIT, PDI |
| Pressure switch | A bubble with PSH, PSL, PSHH or PSLL on an impulse line from the process. | PS, PSH, PSL, PSHH, PSLL |
| Level gauge glass | A tall narrow rectangle beside the vessel, joined to it by two horizontal nozzles (top and bottom), with an LG bubble. | LG |
| Magnetic level gauge | A chamber beside the vessel on two nozzles, with a float inside and a column of indicator flaps (half-filled marks) on its face, and an LG bubble. | LG, LI |
| Displacer level transmitter | An external cage beside the vessel on two nozzles, with a long slender displacer hanging inside from a torque tube at the top, and an LT bubble. | LT, LIT |
| Differential pressure level transmitter | An LT bubble with two impulse lines to the vessel: one from a low nozzle (high side) and one from a high nozzle (low side). Remote seals are drawn as capillaries (line with × marks). | LT, LIT |
| Guided wave radar level transmitter | An LT bubble on a vessel-top (or chamber-top) nozzle, with a straight rod or cable probe running down into the liquid. | LT, LIT |
| Non-contact radar level transmitter | An LT bubble on a vessel-top nozzle, with a cone (horn antenna) pointing down and wave arcs (unguided signal) towards the liquid. | LT, LIT |
| Nuclear (gamma) level transmitter | A source holder (small box) on one side of the vessel and a detector rod on the other, joined by a wavy (radiation) line across the vessel, with an LT bubble on the detector. | LT, RE |
| Vibrating fork level switch | A short side nozzle into the vessel with two small prongs (the fork) inside, and an LS bubble (LSH, LSHH…) outside. | LS, LSH, LSL, LSHH, LSLL |
| Float level switch | A float (circle) on a short arm inside the vessel, pivoted at the wall, with an LS bubble outside. | LS, LSH, LSL |
| Analyser (with sample probe) | An AT (or AE) bubble linked to a probe that dips into the line, with the measured component written beside the bubble (O2, H2S, H2O, OIW, BS&W, CO2…). | AT, AE, AIT, AI |
| Diaphragm (remote) seal with capillary | A small flat seal on the pipe or vessel nozzle (a short rectangle with a curved diaphragm line), joined to a transmitter bubble by a capillary (a line with × marks). | PT, LT |
| Vibration element / transmitter on a machine | A VE (or VT) bubble joined by a short line to a small square or dot on the outline of a motor, pump, compressor or bearing. Often in pairs (A / B or X / Y), one per bearing or per axis, with VI / VA / VSHH functions downstream. | VE, VT, VXE, VYE, VI, VSHH |
3D components for these symbols
Questions
What is the symbol for an orifice plate on a P&ID?
An orifice plate between a flange pair on the line, drawn as a bar across the pipe with a gap for the bore, with two impulse lines from the flange taps up to an FT bubble. See the orifice plate symbol.
How do you tell a flow orifice from a restriction orifice?
Both are a plate between flange bars. A flow-measuring orifice has impulse lines from the taps to a transmitter. A restriction orifice has no taps and is labelled RO or FO.
What does FE mean on a P&ID?
Flow element: F for flow, E for the primary element, the part in the pipe that senses the flow. It is usually paired with an FT, the flow transmitter.
What does a thermowell look like on a P&ID?
In this library, a U-shaped pocket dipping into the line, with a line up to a TE, TT or TI bubble. Some legends draw a short line into the pipe with a dot. The pocket is tagged TW. See the thermowell symbol.
How is a radar level transmitter shown on a P&ID?
A non-contact radar is an LT bubble on a vessel-top nozzle with a cone pointing down and wave arcs towards the liquid. A guided wave radar has a straight rod or cable running down into the liquid instead.
Other symbol categories
- Valves 23
- Check valves 6
- Relief, regulators and safety devices 9
- Actuators, operators and valve accessories 25
- Piping fittings and specials 37
- Lines and signals 16
- Connectors, boundaries and annotations 11
- Instrument bubbles and functions (ISA 5.1) 14
- Vessels, columns and tanks 13
- Heat transfer equipment 12
- Pumps 9
- Compressors, blowers and drivers 15
- Filters, separators and mixers 10
- Flare, wellhead, pipeline and packages 16
- Fire & gas and fire protection 24
- Electrical (single-line) 23