API 682

Shaft sealing systems for centrifugal and rotary pumps

API 682 mechanical seals explained: seal categories 1 to 3, arrangements 1 to 3, types A, B and C, and piping plans such as Plan 11 and Plan 53A.

Scope

API 682 specifies mechanical seals and their support systems for centrifugal and rotary pumps in the petroleum, natural gas and chemical industries. It covers the seal itself, the seal chamber interface, the piping plans that keep the seal faces cool, clean and lubricated, the auxiliary equipment such as reservoirs and coolers, and the qualification testing of seal designs.

On oil and gas facilities, API 610 process pumps are normally fitted with API 682 seals. The datasheet names the seal by its category, arrangement and type, and names the piping plan, for example Category 2, Arrangement 2, Type A with Plans 11 and 52. The same scheme is widely used for chemical pumps too.

Seals for compressors use dry gas seals with their own standards. The pump itself is covered by API 610 or ASME B73.1, and lube oil systems by API 614. ISO 21049 is the related international standard, based on an earlier edition of API 682.

Categories, arrangements and types

A seal is described by three independent choices. The category sets the duty and how the seal is built and tested. The arrangement sets how many seals there are and whether the space between them is pressurised. The type sets the seal design.

ChoiceOptionsMeaning in plain words
Category1For non-API 610 pumps, such as ASME B73 chemical pumps. Commonly quoted range -40 °C to 260 °C
2For API 610 pumps. Commonly quoted range -40 °C to 400 °C
3For API 610 pumps, with the most rigorous qualification testing and documentation. Same range as Category 2
Arrangement1One seal per cartridge
2Two seals with an unpressurised buffer fluid between them
3Two seals with a pressurised barrier fluid between them, so process fluid cannot leak to atmosphere in normal operation
TypeAPusher seal with elastomer O-rings
BMetal bellows seal with elastomer O-rings
CMetal bellows seal with flexible graphite seals, for high temperature

Commonly quoted values from the 4th edition, not a copy of the standard. The categories also have pressure limits, commonly quoted as 20 bar(g) for Category 1 and 40 bar(g) for Categories 2 and 3. Earlier editions stated them in absolute pressure, so take the limits from the edition you use.

Common piping plans

Piping plans are numbered schemes for the fluid that flushes, buffers or barriers the seal. The numbers are shared across the industry, so Plan 53A means the same thing on every datasheet.

PlanWhat it doesTypical use
Plan 11Recirculates process fluid from the pump discharge, through an orifice, into the seal chamberThe default flush for clean fluids on single seals
Plan 52An unpressurised buffer fluid reservoir connected to the space between two sealsArrangement 2 seals
Plan 53AA barrier fluid reservoir pressurised by a gas, usually nitrogenArrangement 3 seals
Plan 54A pressurised barrier fluid supplied by an external systemArrangement 3 seals where a separate barrier system is used

A short selection. The standard defines many more plans, and project specifications often add instruments to them.

Edition

The current edition is the 4th, published in May 2014 and reaffirmed in 2022. It covers shaft sizes of about 20 to 110 mm. A 5th edition is in preparation, so check the API catalogue before you cite one.

Key concepts

Mechanical seal
Two flat rings, one turning with the shaft and one fixed, pressed together by springs or bellows. A very thin fluid film between the faces lubricates them and limits leakage.
Cartridge seal
The seal, sleeve and gland come as one pre-assembled and pre-tested unit. It is fitted without setting the faces by hand, which reduces mistakes on site.
Buffer and barrier fluid
In a dual seal the space between the two seals holds a clean fluid. A buffer fluid is at a lower pressure than the seal chamber, so a leak across the inner seal goes into the buffer system. A barrier fluid is at a higher pressure, so a leak across the inner seal is barrier fluid going into the process, not process fluid coming out.
Seal chamber
The space around the shaft where the seal sits. API 610 pumps have large seal chambers sized to take API 682 cartridge seals.
Qualification testing
Seal designs are tested on representative fluids under set conditions before they can be offered as API 682 seals. Category 3 seals have the most extensive testing and documentation.
Default selections
The standard gives default choices to simplify specification, which the purchaser can change. Many datasheets accept the defaults and only state the exceptions.

Questions

What is the difference between seal categories 1, 2 and 3?

Category 1 seals are for non-API 610 pumps, such as ASME B73 chemical pumps, with a lower temperature limit. Category 2 seals are for API 610 pumps. Category 3 seals are also for API 610 pumps but have the most rigorous qualification testing and documentation.

What is an Arrangement 2 seal?

Two seals in series with an unpressurised buffer fluid between them, often supplied by a Plan 52 reservoir. If the inner seal leaks, the leak goes into the buffer system, where it can be detected, and the outer seal still contains it.

What is API Plan 53A?

A seal support system for dual pressurised seals. A reservoir of barrier fluid is pressurised by nitrogen or another gas, above the seal chamber pressure, and the fluid circulates between the seals. The centrifugal pump includes a Plan 53A reservoir.

What is the current edition of API 682?

The 4th edition, from 2014, reaffirmed in 2022. ISO 21049:2004 is based on an earlier edition, so the two differ. A 5th edition is in preparation, so check the API catalogue.

In Deck Twin

The centrifugal pump cites API 682 Plan 53A and draws a seal reservoir beside the pump. The vertical inline pump cites Plan 11 and draws a cartridge seal with its flush line, and the multistage pump cites API 682 and draws seal coolers at both ends. These are generic layouts. The library does not select seals or size support systems.

Deck Twin uses these standards as reference values for visualisation. Check the current edition of each standard before using any value for design, procurement or fabrication.

Components that follow API 682 3