API 616

Gas turbines for the petroleum, chemical and gas industry services

API 616 covers industrial and aeroderivative gas turbines for generator and mechanical drive, with their enclosure, fuel, air and lube systems.

Scope

API Std 616 specifies open, simple-cycle and regenerative combustion gas turbines for driving generators, compressors and pumps. It covers the turbine, its accessories and auxiliaries: inlet air filtration, enclosure, fuel systems, starting, lube oil, controls, fire protection and testing.

On oil and gas facilities, gas turbines are the main power source offshore and the usual driver for large export and injection compressors. They burn the facility's own fuel gas and often have diesel as a backup fuel.

Driven compressors are covered by API 617, gears by API 613, couplings by API 671 and lube systems by API 614. ISO 3977 is a related series for gas turbine procurement.

Key concepts

Industrial and aeroderivative
Industrial (heavy-duty) turbines are robust machines designed for long running. Aeroderivative turbines are developed from aircraft engines, are lighter and more compact, and are widely used offshore where weight matters.
Single-shaft and two-shaft
A single-shaft turbine runs at constant speed and suits generator drive. A two-shaft turbine has a free power turbine that can run at variable speed, which suits compressor drive.
Site rating
Output is quoted at ISO conditions (15 °C, sea level, 60 % relative humidity), then corrected for the site. Output falls in hot weather and with inlet and exhaust pressure losses.
Inlet air filtration
Offshore air carries salt and water, which foul and corrode the compressor. Filter houses use weather hoods, vane separators, coalescers and final filters, and may add anti-icing in cold climates.
Enclosure and fire protection
The turbine sits in an acoustic enclosure with ventilation, gas and fire detection, and a fire suppression system such as CO₂ or water mist. Ventilation must be shut and suppression released in a defined sequence.
Fuel systems
Gas, liquid and dual-fuel systems are defined. Dual fuel lets the turbine change over to diesel if fuel gas is lost.

In Deck Twin

The gas turbine generator takes mw, fuel (gas or dual), a fuel gas inlet size and rating, stackHeight, cutaway and doorsOpen. It draws the enclosure, filter house, exhaust, gearbox, generator and auxiliary skids. The gas-turbine-driven compressor train uses a two-shaft turbine to drive an API 617 compressor. Sizes scale from mw using generic proportions, not any maker's engine.

Deck Twin uses these standards as reference values for visualisation. Check the current edition of each standard before using any value for design, procurement or fabrication.

Components that follow API 616 3