API 598
Valve inspection and testing
API 598 valve testing explained: shell, backseat, low-pressure and high-pressure closure tests, which valves they apply to, and API 598 vs ISO 5208.
Scope
API 598 covers the inspection, examination and pressure testing of valves by the manufacturer. It applies to gate, globe, plug, ball, check and butterfly valves, with metal, resilient or other non-metallic seats. It sets which tests each valve gets, the test fluid, the pressure, how long the pressure is held and how much seat leakage is allowed.
On oil and gas facilities it is the test standard commonly called up for valves to API 600, API 602, API 608 and API 609. A purchaser can also ask for inspection at the maker's works, and API 598 sets out what the inspector may check.
It does not cover pipeline valves to API 6D or wellhead valves to API 6A, which have their own test requirements. Fire testing is covered by API 607 and API 6FA, and fugitive emission testing by API 622, API 624 and ISO 15848.
The tests in API 598
Each valve gets a shell test. The closure tests that apply depend on the valve type, size and class, and the standard sets them out in a table by valve type.
| Test | What it checks | Usual test fluid | Applies to |
|---|---|---|---|
| Shell test | The body and bonnet hold pressure without leaks, with the valve partly open | Water or other liquid | Every valve |
| Backseat test | The backseat on the stem seals against the bonnet when fully open | Water or other liquid | Valves with a backseat feature, mainly gate and globe valves |
| Low-pressure closure test | The seat seals at low pressure | Air or inert gas | Seat test for many valve types and sizes |
| High-pressure closure test | The seat seals at high pressure | Water or other liquid | Seat test for many valve types and sizes |
Which closure test is required, and whether both are, is set by valve type, size and class in the standard. The commonly quoted shell test pressure is 1.5 times the valve's pressure rating at 38 °C (100 °F), and the high-pressure closure test is commonly 1.1 times that rating. These are commonly quoted values, not a copy of the standard.
Seat leakage
For soft seats, the commonly quoted requirement is no visible leakage. Metal-seated valves may show a small leakage during the closure test, limited by size, counted as drops of liquid or bubbles of gas per minute.
If a valve needs tighter shut-off, the purchaser asks for it on the datasheet, for example by naming a leakage rate from ISO 5208 or a project specification.
Edition
The current edition is the 11th, published in February 2023. Check the API catalogue for a later edition before you cite one.
Key concepts
- Shell test
- A pressure test of the body and bonnet with the valve partly open, so the whole pressure boundary is loaded. No visible leakage through the walls or the body joints is allowed.
- Closure test
- A seat test with the valve closed and pressure on one side. Bidirectional valves are tested in both directions.
- Test duration
- Each test pressure is held for a minimum time that grows with valve size, so a leak has time to show. The times are set in the standard.
- Backseat
- A seat on the stem that closes against the bonnet when the valve is fully open. It isolates the packing so that it can be adjusted. Many sites do not allow repacking under pressure.
- Inspection at the works
- A purchaser's inspector can witness tests and examine valves before they ship. The standard defines what that inspection can include.
- Test fluid
- Liquid tests usually use water with a corrosion inhibitor, with limits on chlorides for austenitic stainless steel. Gas tests use air or an inert gas.
Questions
What is API 598?
API 598 is the standard for valve inspection and testing. It sets the shell, backseat and seat closure tests a manufacturer does on gate, globe, plug, ball, check and butterfly valves, and the leakage allowed. The current edition is the 11th, published in 2023.
What is the shell test pressure in API 598?
The commonly quoted shell test pressure is 1.5 times the valve's pressure rating at 38 °C (100 °F), held with the valve partly open. Check the current edition for the exact rule and the hold times.
What is the difference between API 598 and ISO 5208?
Both cover the pressure testing of industrial valves. ISO 5208 defines a set of leakage rates, from zero visible leakage upwards, that a purchaser can choose from. API 598 sets its own allowed leakage for each seat type and size.
Does API 598 apply to API 6D valves?
No. API 6D pipeline valves are tested to the requirements in API 6D itself, which include their own hydrostatic shell and seat tests and optional gas tests.
In Deck Twin
No component cites API 598. It applies to the valves the library draws, such as the gate valve, globe valve, ball valve, butterfly valve and swing check valve. The library does not model testing.
Deck Twin uses these standards as reference values for visualisation. Check the current edition of each standard before using any value for design, procurement or fabrication.